Call Us: 0812 8888 7956

SINGLE CASE 2” Model ST-40-DI

SINGLE CASE 2” Model ST-40-DI

Brand: TechnipFMC

Penjelasan Produk :

 

2” Model ST-40-DI

SMITH METER PD METERS

The Smith Meter Model ST-40 is a DN50 (2*) single case, straight-through, rotary vane positive displacement meter commonly used on tank trucks and as a line meter. Applications include: blending, batching, dispensing, inventory control and custody transfer of oils, solvents, chemicals, paints, fats, and fertilizers.

 

FEATURES

Superior Accuracy – The smith meter rotary vene meter principle and unique offset, inlet, and outlet nozzles combine to minimize pressure drop across the measuring chamber for reduced flow through the meter clearances for maximum accuracy.

Low Pressure Drop – Streamlined flow path provides low pressure drop.

Positive and Accurate Registration – High torque drive calibrator with aadjusment in 0.05% increments ensures accurate registration.

Long Service Life – Low friction ball bearings, fixed cam timing, and rugged construction give sustained accuracy and long life.

Ductile Irin Housing – For a maximum working pressure at 16 bar.

PED¹ - Liquid Complaint.

OPERATING SPECIFICATIONS

MAXIMUM FLOW RATE

 

USGPM

L/min

Continuous Rating - Standard Trim

85

320

Intermittent Rating² - Standard Trim

105

400

Continuous/Intermittent Rating - All Iron Trim

75

285

MINIMUM FLOW RATE TYPICAL PERFORMANCE

 

Viscosity (mPa.s)

Linearity³

Units

0.5

1

5

20

100

400

±0.15%

USGPM

15

10

4

1

0.2

0.05

L/min

56.5

37.5

15

3.8

0.75

0.19

±0.25%

USGPM

10

7.5

3

0.75

0.15

0.04

L/min

37.5

28.5

11

2.9

0.6

0.15

±0.50%

USGPM

7.5

5

2

0.5

0.1

0.03

L/min

28.5

19

7.5

1.9

0.4

0.1

Temperature

Standard Meter Clearances, with -

Buna-N : -20°C to 65°C (-4°F to 150°F)

Viton seals : -12°C to 65°C (10°F to 150°F)

High Temperature meter Clearances, with -

Buna-N : -20°C to 93°C (-4°F to 200°F)

Viton seals : -12°C to 93°C (10°F to 200°F)

All Iron Trim, With -

Buna-N : -20°C to 108°C (-4°F to 225°F)

Viton seals : -12°C to 150°C (10°F to 300°F)

Optional Low Temperature :

−29°C (-20°F) at reduced working pressure of 10 bar (1,000 kPa), with Buna-N Seals.

Special low temperature of -40°C (-40°F) on request

Meter Gearing

One dekalitre per revolution of meter calibrator output shaft.

 