AQUA Metro Technical Data CONTOIL® VZO/A Mechanical Display
Brand: AQUA METRO
Features |
· State-of-the-art-design |
· Electronic counter, mass flow, volume flow indication, multiple output signals |
· Integrated temperature sensor |
· No straight inlets or outlets required |
· Indefendent of viscosity and temperature |
· High vibration resistance |
· Optional; metrological type approval |
· Automatic medium switch based on temperature |
Benefits |
· Mass flow mesurements |
· Highly flexible mounting with ver small space requirements |
· Reliable monitoring and flexible control of the system |
· Accurate measurements |
· A reliable solution with everything from a single supplier |
· Simplifies consumption optimzing |
Technical data CONTOIL® VZO/A |
|||||||
Mechanical display |
|
Meter DN size |
|||||
Nominal diameter |
DN MM |
15 |
20 |
25 |
40 |
50 |
|
|
|
inch |
½ |
¾ |
1 |
1½ |
2 |
Smallest readable amount |
I |
0.01 |
0.1 |
0.1 |
0.1 |
1 |
|
maximum registration capacity |
m³ |
1000 |
10000 |
10000 |
10000 |
100000 |
|
registration time until overrun to zero at |
Qcount (m³) |
h |
2500 |
10000 |
5000 |
1667 |
5000 |
RV: Reed pulser with decadic pulse values |
|||||||
Ambient temperature |
|
°C |
−10 to +70 |
||||
Switching elemet |
Reed contact |
||||||
Switching voltage max |
VDC?VAC |
48 |
|||||
Switching current max |
mA |
50 (Ri 47Ω / 0.5 W) |
|||||
Static current |
open contact |
||||||
Switching power max |
W |
2 |
|||||
one time |
% |
50 +/-10% |
|||||
RV Reed |
|
|
DN 15 |
DN 20 |
DN 25 |
DN 40 |
DN 50 |
I/pulse |
0.1 |
1 |
1 |
1 |
10 |
||
I/pulse |
1 |
- |
- |
10 |
100 |
||
Pulse value |
|
|
see type plate |
|
|
|
|
Protection class |
IP 656 |
||||||
Connection |
|
|
permanent mouted cable. 3 m long. 2 x 0.14 mm² |
||||
cross section |
IN: Inductive pulser with decadic pulse values |
|||
Supply |
|
VDC |
5 − 25 |
Nominal voltage |
VDC |
8.2 (Ri approx. 1 Ω) |
|
Ambient temperature |
|
°C |
− 10 to +70 |
protection class |
|
|
IP 65 |
Switching element |
Slot intiator acc.to IEC 60947-5-6 (IN-NAMUR) |
||
Switching frequency |
Hz |
0 to 3000 |
|
Residual ripple |
<5 % |
||
Switching current |
|
mA |
≥3 (at 8.2 V, 1 kΩ) |
Static current zero |
mA |
≤1 (at 8.2 V, 1 kΩ) |
|
pulse values for remote transmitter |
|
|
DN 15 DN 20 DN 25 DN 40 DN 50 |
IN (NAMUR) inductive (IEC 60947-5-6) |
I/pulse |
0.01 0.01 0.1 0.1 1 |
|
pulse frequency IN |
Qmax |
Hz |
16.667 41.667 8.333 25.000 8.333 |
Qmax |
Hz |
0.278 0.8333 0.208 0.625 0.208 |
|
Connection |
|
|
Connection cable min 2 x 0.35mm² and 5.5 - 13mm |
external cable diameter on plug |
|||
(Prefabricated cable available) |