Technical data CONTOIL® DN 15 - 50 |
|||||||
Hydraulic |
Meter DN size |
||||||
Nominal diameter |
|
DN mm |
15 |
20 |
25 |
40 |
50 |
inch |
½ |
¾ |
1 |
1½ |
2 |
||
Installation length |
|
mm |
165 |
165 |
190 |
300 |
350 |
Nominal Pressure threaded ends |
PN |
bar |
16 |
16 |
16 |
16 |
N/A |
Nominal pressure flanges |
PN |
bar |
25/40 |
25/40 |
25/40 |
25/40 |
25/40 |
Max.medium temperature |
Tmax |
°C |
130/180 |
||||
Maximum flow rate |
Qmax1) |
l/h |
600 |
1500 |
3000 |
9000 |
30000 |
Continuous flow rate |
Qcont2) |
l/h |
400 |
1000 |
2000 |
6000 |
20000 |
minimum flow rate |
Qmin |
l/h |
20 |
40 |
75 |
225 |
750 |
Approx.starting flow rate |
l/h |
4 |
12 |
30 |
90 |
300 |
|
Max.permissible error of actual value1) |
VZF II, VZO, DFM |
±10% |
±10% |
±10% |
±10% |
±10% |
|
VZFA II, VZOA |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
||
VZFA II, linearized |
±0.3% |
±0.3% |
±0.3% |
±0.3% |
±0.3% |
||
Repeatability |
±0.1% |
±0.1% |
±0.1% |
±0.1% |
±0.1% |
||
Measuring chamber volume |
cm³ |
|
12 |
36 |
100 |
330 |
1200 |
Safety filter mesh size |
mm |
|
0.400 |
0.400 |
0.0400 |
0.800 |
0.800 |
Weight with threaded ends3) |
kg |
2.2 |
2.5 |
4.2 |
17.3 |
- |
|
Weight with flanges PN 25 |
kg |
3.8 |
4.5 |
7.5 |
20.3 |
41.0 |
|
Weight with flanges PN 40 |
kg |
|
4.4 |
5.5 |
7.8 |
20.5 |
42.0 |
Hydraulic Material |
|
|
|
|
|
|
Part |
Material |
15 |
20 |
25 |
40 |
50 |
Housing with threaded ends |
Cast Brass |
∞ |
∞ |
∞ |
||
spheroidal graphite iron GIS 400-15 |
∞ |
|||||
Housing with flanged ends |
spheroidal graphite iron GIS 400-15 |
∞ |
∞ |
∞ |
∞ |
∞ |
Measuring chamber PN 16/25 |
Cast Brass |
∞ |
∞ |
∞ |
∞ |
|
Alu-Bronze |
∞ |
|||||
Measuring Chamber PN 40 |
Stainless steel |
∞ |
∞ |
∞ |
∞ |
∞ |
Seals |
FPM fluorelastomer |
∞ |
∞ |
∞ |
∞ |
∞ |
rotary piston |
Anodized alumunium |
∞ |
∞ |
∞ |
∞ |
∞ |
Ancillries |
Plastic |
∞ |
∞ |
∞ |
∞ |
∞ |
Housing finish |
Enameled red, RAL 3013 |
∞ |
∞ |
∞ |
∞ |
∞ |