FLOWPET-5G OVAL
Brand: OVALPenjelasan Produk :
FLOWPET-5G OVAL
· General
FLOWPET-5G is an OVAL flowmeter primarily intendedfor use in boiler feed water and fuel oil metering applications. Field proven accuracy and long life along with the best price/peformance and ease of use make this industrial meter ideal as a dedicated tool for heat control.
· FEATURES
1. Available in two product families-for water service and fuel oil service.
2. Newly designed electronic register shows total flow and instantaneous flow on a digital LCD at the touch of mode elect switch. The display angel can be adjusted for better visibility (Adjustable range: 90 degrees upward, 75 degrees downward).
3. The electronic register equipped models have an internal battery (good for 8 years): eliminates the need for an external power source. (operation on external power source is recommended for the pulse output models).
4. Improved display capabilities compared to the previous EG register.
5. Factored pulse width is variable in 1ms steps with the front panel buttons (adjustable 1 to 999ms).
6. Simulated outputs available. (Pulse generator furnished meter only)
7. Reliable engineering-unit pulse for total flow and fast pulse output are available.
8. Analaog output available (2-wire, 4to 20mA)
|
Product Code No. |
Nominal Size Flange Rating |
L |
A |
Flange |
Approx Weight kg |
Net Mesh |
Max. Flowrate L/h |
Pressure Loss (kPa) at max. Flowrate |
Applicable Flowpet-5G |
|||
|
D |
t |
P.C.D |
nΦh |
|||||||||
|
SS5278A |
20A JIS 10K RF |
125 |
82 |
100 |
18 |
75 |
4-15 |
3.4 |
80 |
1200 |
2 |
LS5277-5□□B |
|
SS5378A |
20A JIS 10K RF |
140 |
104 |
125 |
18 |
90 |
4-19 |
5.3 |
60 |
3600 |
6 |
LS5377-5□□B |
|
SS5578A |
20A JIS 10K RF |
170 |
129 |
140 |
20 |
105 |
4-19 |
7.7 |
60 |
7200 |
6 |
LS5577-5□□B |
|
SS5678A |
20A JIS 10K RF |
190 |
153 |
155 |
20 |
120 |
4-19 |
9.6 |
60 |
12000 |
6 |
LS5677-5□□B |
|
Electronic Register : Units of Count and Pulse Output Units |
||||||||||||||
|
Model |
Nom Size. mm |
Totalizer Resolution |
Output Pulse |
Full Scales(st'd) |
Max. Flowrate L/h |
|||||||||
|
Fsctored output pulse |
Factored pulse width |
Unfactored output pulse |
Units of instantaneous flowrate L |
|||||||||||
|
Pulse Units |
Output freq. At max. Flowrate |
1ms |
50ms |
100ms |
250ms |
Nom.meter factor |
Output freq. At max. Flowrate |
/h (mode b1) |
/min (mode b2) |
|||||
|
LS5277-5□□B |
20 |
999999.99 |
10mL/P |
33.3 |
⃝ |
- |
- |
- |
918mL/P |
33.6Hz |
1 |
0.01 |
1200 |
|
|
9999999.9 |
100mL/P |
3.33 |
⃝ |
⃝ |
⃝ |
- |
||||||||
|
99999999 |
1L/P |
0.33 |
⃝ |
⃝ |
⃝ |
⃝ |
||||||||
|
LS5377-5□□B |
25 |
999999.99 |
10mL/P |
10.0 |
⃝ |
⃝ |
- |
- |
17.955mL/P |
55.7Hz |
1 |
0.01 |
3600 |
|
|
9999999.9 |
100mL/P |
1.00 |
⃝ |
⃝ |
⃝ |
⃝ |
||||||||
|
99999999 |
1L/P |
0.10 |
⃝ |
⃝ |
⃝ |
⃝ |
||||||||
|
LS5577-5□□B |
40 |
999999.99 |
10mL/P |
20.0 |
⃝ |
- |
- |
- |
35.496mL/P |
56.3Hz |
1 |
0.01 |
7200 |
|
|
9999999.9 |
100mL/P |
2.00 |
⃝ |
⃝ |
⃝ |
⃝ |
||||||||
|
99999999 |
1L/P |
0.20 |
⃝ |
⃝ |
⃝ |
⃝ |
||||||||
|
LS5677-5□□B |
50 |
9999999.9 |
100mL/P |
33.3 |
⃝ |
- |
- |
- |
76.455mL/P |
43.6Hz |
1 |
0.01 |
12000 |
|
|
99999999 |
1L/P |
3.33 |
⃝ |
⃝ |
⃝ |
- |
||||||||
|
99999999 |
10L/P |
0.33 |
⃝ |
⃝ |
⃝ |
⃝ |
||||||||