Multimag ITRON Woltex DN250 20in
Brand: ITRON TMIIWoltex is a horizontal helix Woltmann meter, available in sizes from DN 50 to 500.
Extended Approved RangeWoltex is approved with normal flow range as per ISO 4064-1:1993, as class B and also, with superior permanent flow-rate. It means that one size (DN) has 2 different flow range :- N for Normal Permanent Flow Rate;- G for Greater Permanent Flow Rate;Greater version is special for metering points where peak flows are recurrent.
Typical Perfomance |
|
|
Nominal Diameter (DN) |
DN250 10in |
|
Starting Flowrate |
3 m3/h |
|
Accuracy ±2% from* |
5 m3/h |
|
Accuracy ±5% from* |
3.5 m3/h |
|
Admissible peak flow (102 max) |
1500 m3/h |
|
Max. Admissible flowrate (continuous) |
1200 m3/h |
|
Head loss at Qmax |
0.12 bar |
|
Max. Admissible temperature |
50°C |
|
Max. Admissible pressure |
20 bar |
|
Min. Scale interval |
20 L |
|
Indicating range |
99999999 m3 |
|
Cyble HF pulse weight |
1000 L |
|
EE Approval Values |
|
|
Nominal Diameter (DN) |
DN250 10in |
|
EEC/ISO Class approval |
Class B Positions |
|
Nominal flowrate Qn |
G 600 m3/h |
|
N 400 m3/h |
|
|
Max. Flowrate Qmax |
G 1200 m3/h |
|
N 800 m3/h |
|
|
Accuracy ±2% class B: Qt from |
G 120 m3/h |
|
N 80 m3/h |
|
|
Accuracy ±5% class B: Qmin from |
G 18 m3/h |
|
N 12 m3/h |
|
|
Max. Temperature |
30°C |
|
EEC approval certificate |
F-02-G071 |
|
Dimensions |
|
|
End connetion* |
Flange PN 10/16 |
|
>Meter |
|
|
A (lenght) |
ISO |
450 mm |
DIN |
- |
|
ISO long |
- |
|
AS (Australia/UK) |
- |
|
B |
|
214 mm |
C |
|
136 mm |
D |
|
204 mm |
E |
|
195 mm |
F |
|
399 mm |
G |
|
405 mm |
H |
|
395 mm |
Weight |
|
75 kg |
>Mechanism |
|
|
L |
|
256 mm |
I (max. Width) |
|
276 mm |
M |
|
195 mm |
Weight |
|
8.5 kg |