Call Us:0812 8888 7956

AQUA METRO Technical Data CONTOIL® VZF/A II

AQUA METRO Technical Data CONTOIL® VZF/A II

Brand: AQUA METRO

Features

· State-of-the-art-design

· Electronic counter, mass flow, volume flow indication, multiple output signals

· Integrated temperature sensor

· No straight inlets or outlets required

· Indefendent of viscosity and temperature

· High vibration resistance

· Optional; metrological type approval

· Automatic medium switch based on temperature

Benefits

· Mass flow mesurements

· Highly flexible mounting with ver small space requirements

· Reliable monitoring and flexible control of the system

· Accurate measurements

· A reliable solution with everything from a single supplier

Simplifies consumption  optimzing

Technical data CONTOIL® VZF/A II

             

Electronic display

             

Nominal diameter

 

DN mm

15

20

25

40

50

   

inch

½

¾

1

2

Max. Medium temperature

Tmax

°C

130, 180

Max. Environment temperature

 

°C

−25 to +70

Max. Stroge temperature

 

°C

−25 to +80

Protection class

rhmax

% rh

95, non condensing

 

   

IP 66 / IP 68 / IP 69

Total volume / mass

 

I, m3, G1)

Max.3 decimals (dynamic)

   

kg, t, lb

 

Resettable volume / mass

 

I, m3, G1)

Max.3 decimals (dynamic)

   

kg, t, lb

 

Flow rate

   

Max.3 decimals (dynamic)

Smallest readable amount

 

 

0.001

 

 

 

 

maximum registration capacity

   

8 digits

       

Registration time until overrun to zero at

Qcount (m³)

 

>100 years

     

Data preservation

 

 

by non-volatile memory (EEPROM)

Outputs

   

 

3 (2 pulse / frequency, 1 analog 4-20 mA)

 

 

freely selectable, totally independent of each other

pulse output

 

 

volume or mass pulse 0-200 pulse/sec.(50% duty cycle)

Current 4-20 mA

 

 

volume flow, mass flow or temperature signal

Frequency

Qmin, Qmax

 

volume flow, mass flow or temperature minimum

     

maximal and hystersis paramerized

   

Limit switch

Qlimmax, Qlimmin

allows you to set an alet  whenever predefined

     

flow rates are exceeded (NC/NO)

Flow meter state switch

Alarm, Error

state and on/of parameterized (NC/NO)

Electronic

   

Power supply

VDC

6 − 30

Quiescent current zero

mA

4

Relais output

 

 

Switching element

 

solid state relay (out1 & out2)

Resistance ON

≤40

Resistance OFF

MΩ

≥10

Max. Supply voltage

VDC

≤48

Max. Switching current

mA

≤50

Pulse width

ms

2-500 (dynamic)

Pulse frequency

Hz

0 - 200

Current output

 

 

Analog output

mA

4 - 20 passive

Resolution

bit

26

Max. Error

mA

±0.2

Update interval

s

<0.1 s

Maximum Load (RL)

0 to 1116. depending on external supply voltage

   

of the power supply unit  U-6

   

        _____   Ω;(e.g.: 1116O@30V)

   

      0.0215